Dynamic Insulation products are available for different construction types and panel thicknesses. Dynamic Cavity Full Fill products are designed for use in conventional masonry construction with full-fill cavity insulation. For a typical masonry house archetype Dynamic Cavity Full-Fill*:

icon_pound Improves the U-value of the fabric to 0.15 in thin walls (100mm cavity)

icon_pound Delivers a saving of 1.88 SAP DER points and Carbon Reduction of circa £7.50 kgCO2/m2

icon_tick Enables the use of a simpler and less expensive ventilation system

icon_house Improves indoor thermal comfort and air quality


Case Study

Energyflo-Inside-smallSee how Chorleywood Homes are using Dynamic Insulation to meet Code with no increase in cost or change to familiar building methods.

View Case Study

Dynamic Insulation products for full fill cavity-wall insulation in traditional new build masonry external walls are designed for installation during construction.  The insulation panels are fully interlocking and dry fixed to the face of the inner leaf of masonry as per normal insulation.

The external faces (front and back) of the panels also incorporate vertical grooves that act as guidelines for cutting the panels. The front face also incorporates tapered flutes to provide a drainage plane and shed water away from the internal leaf. In accordance with BS 5628-3:2005 the panels are designed to prevent water reaching the inner leaf. The flute detail also ensures that water penetrating the outer leaf of the wall will drain down the cavity face of the outer leaf, therefore satisfying the respective national regulations for buildings.

Panels can be trimmed along the vertical grooves on the face of the panel using normal rigid insulation working tools.  Once installed the Dynamic Insulation system acts as an air supply to all types of mechanical ventilation systems.

Dynamic Insulation full fill cavity-wall insulation panels are available in 100, 125 and 150mm thicknesses in two types of insulation material; 

  • Standard Expanded Polystyrene; ‘K’ value of 0.038W/m.K.
  • Carbon enriched Premium Expanded Polystyrene; ‘K’ value of 0.030W/m.K.

 

The Dynamic Insulation full fill cavity-wall insulation system is made up of 3 panel types:

  1. BC Panels (Base Channel Panel) : specified to permit air inlet to the channel i.e. at the bottom of the wall and (if required) above the ground storey air intake point.
  2. H Panels (Half Height Panel) : 225mm in height and is specified to ensure that the dynamic insulation layer finishes one block below the air intake point specified on the drawing.
  3. CC Panels (Collector Channel) : specified at the air intake point. Specification of air intake point is defined by the choice of ventilation system.

 

[*Assumptions]

Detached House

masonry_full_detached

Semi Detached

masonry_full_semi

Dynamic_Cavity_Masonry_Full_and_Partial_Fill_XSCW_Diagram-sm

U Value Calculator

Click the link below to calculate
your U-values and SAP
DER improvement points

Go to Calculator

Get in touch

Find out if Dynamic Insulation
can help you meet Code with no
increase in cost or change to
familiar building methods.

Contact Us